12g/M Petn Core Load Detonating Cord

Our 12 g/m PETN core detonating cord delivers consistent propagation energy per metre for professional blasting and initiation systems. Manufactured and QA-tested for reliability, this detonating cord is used by licensed contractors for trunking, priming, and line initiation where certified explosives are permitted. Supplied only to authorised buyers with full documentation and transport compliance.

✅ 12 g/m PETN Core Detonating Cord – High Energy per Metre
✅ PETN Core – Consistent Propagation Velocity & Energy
✅ 12 g/m Linear Charge Loading – Engineered for Reliable Transfer
✅ Robust Sheath – Weather & Abrasion Resistant
✅ UN-Compliant Packaging – Certified for Transport & Storage
✅ Batch Traceability – Factory QA & Test Records
✅ Licensed Supply Only – SDS & Compliance Docs Provided
✅ Bulk & Project Supply – Custom Lengths Available
✅ Technical Support – Regulatory & Logistics Assistance

Category:

Description

12 g/m PETN Core Load Detonating Cord – Reliable Linear Explosive for Controlled Blasting

Market Overview

Detonating cords are widely used in mining, tunnelling, and demolition operations due to their ability to deliver a precise, continuous explosive transfer line. With a core load of 12 grams of PETN per metre, this cord strikes a balance between reliability and manageable explosive power, making it suitable for medium-to-large blasting applications.

The demand for detonating cords continues to grow globally as industries prioritise efficiency, compliance, and environmental safety. PETN-based cords remain essential in both civil and mining projects because of their versatility, stability, and effectiveness.

For a comprehensive overview of modern blasting cord technologies, consult Recent Advances in Detonating Cord Systems ↗.


Product Specifications

Parameter Specification Standard/Test Application Impact
Core Load 12 g/m PETN ISO/QC Verified Reliable detonation transfer
Chemical Formula C₅H₈N₄O₁₂ (PETN) CAS 78-11-5 High-energy performance
UN Classification UN 0065, Cord Detonating, Class 1.1D UN/DOT/IATA Safe global transport
Detonation Velocity ~6,500–7,000 m/s Factory Testing Precision linear initiation
Construction PETN core with protective sheath ASTM D256 Durability in varied conditions
Packaging Coils, reels, drums (UN-approved) Manufacturer QC Secure bulk distribution
Applications Mining, Quarrying, Tunnelling, Demolition Industry Guidelines Versatile blasting support

Technical Features

The 12 g/m PETN detonating cord is engineered for consistent initiation and reliable field performance:

  • Continuous linear PETN charge for uniform detonation.

  • Rugged sheath resistant to abrasion, moisture, and handling damage.

  • High detonation velocity ensures reliable transfer between charges.

  • Flexibility allows easy routing in blast layouts.

  • Manufactured under strict quality assurance with batch traceability.


Applications & Benefits

Mining Operations

Detonating cords are vital in open-pit and underground mines for initiating multiple charges simultaneously. The 12 g/m PETN cord ensures predictable energy transfer, supporting fragmentation control and operational safety.

Quarrying

In quarry blasting, the cord provides reliable initiation across rows of boreholes, improving fragmentation and reducing oversize rock.

Tunnelling

For controlled excavation in tunnels, the cord supports precise sequencing, minimising ground vibration and structural impact.

Demolition

Authorised demolition teams use detonating cords in engineered sequences to achieve predictable results while ensuring safety and compliance.

For further reading on vibration control and safe blasting, explore the ITA-AITES Vibration Control Guidelines ↗.


Safety, Storage & Handling

The 12 g/m PETN detonating cord is classified under UN 0065, Class 1.1D, and is subject to strict handling and transport regulations.

  • Must be stored in licensed explosive magazines.

  • Transport restricted to authorised carriers under ADR/IMDG/IATA rules.

  • Only certified and licensed users may purchase and deploy.

  • Supplied with Safety Data Sheets (SDS) and compliance certificates.

For global guidance on safe handling and international storage, refer to the International Ammunition Technical Guidelines (IATG) ↗.


Quality Control & Validation

Manufacturers implement rigorous testing before distribution, including:

  • Detonation velocity consistency checks.

  • Tensile and environmental durability testing.

  • Batch traceability and documentation audits.

  • UN-approved packaging inspections.


Environmental Considerations

Responsible blasting practices with detonating cords aim to reduce community and environmental impacts. Key measures include:

  • Monitoring ground vibration and air overpressure.

  • Reducing flyrock and dust through blast design.

  • Applying controlled fragmentation to minimise waste.


Supply Chain & Support

Authorised suppliers provide:

  • Global bulk supply with UN-compliant transport.

  • Technical support for blast design and deployment.

  • Operator training for licensed professionals.

  • Regulatory paperwork and compliance verification.

Reviews

There are no reviews yet.

Be the first to review “12g/M Petn Core Load Detonating Cord”

Your email address will not be published. Required fields are marked *

TOP